  • Steam Commercial Boilers - Frank I. Rounds Company

    The ClearFire-H (horizontal design) commercial steam boilers both offer 8 sizes up to 60 HP with high efficiency and low NOx technology.. The CBT is a high-efficiency tubeless vertical boiler design up to 30 HP that reliably delivers reliable steam for your process application.. Size range: 10 HP – 60 HP Uses: For comfort heat and process applications for schools, commercial buildings Learn More

  • How Are Water Softeners Used in Steam Boilers

    How Are Water Softeners Used in Steam Boilers Liming 11:12:07. One of the most important accessories for steam boiler is a water softener, which serves several purposes and plays a crucial role in helping the industrial steam boiler avoid malfunctions and run more efficiently.Learn More

  • 200 Horse Power (hp) Capacity, 250 psig Design Pressure

    Aug 21, 2021 · Nationwide™ Boiler's ultra-low NOx, 200 hp (6,900 lbs/hr) Mobile Steam Plant is an open-trailer system, designed at 250 psig pressure, firing natural gas. It is fully piped and wired and includes the following componentsLearn More

  • WBT Steam Boiler Supply, Rental and Maintenace services

    LAUNDRY BOILER - Oil/Gas (40 - 350 kg/h) KSA SERIES - Made in Saudi Arabia . Steam generation capacity: 40 kg/h - 350 kg/h. Operating Pressure: 1-8 BarLearn More

  • Water softener use for a steam boiler - good idea

    Mar 21, 2012 · water softener for untreated steam boiler - good idea? the steam boiler is a commercial boiler (14 sections cast iron) it is not being treated chemically and the makeup water quality is on the very hard side. 0. nicholas bonham-carter Member Posts: 8,488. March 2012.Learn More

  • Converting Boiler steam rating from Kg/hr to Liters of

    Nov 20, 2008 · The boiler is a industrial steam boiler, which uses the steam for the process on site ( brewing boooz ) in this case. in the past I have always been given the steam rating in LB/HR and have used the following; boiler capacity - 15000 lb.hr x 2 Devided by 10 x 4.54 = water capacity of 13620litres.Learn More

  • BASIC WATER TREATMENT OF STEAM BOILERS

    May 02, 2000 · BASIC WATER TREATMENT OF STEAM BOILERS Steve Kenny and Dave Pope Chemco Water Technology Vancouver, WA This is a brief discussion on low-pressure steam boiler chemistry. It provides dry kiln boiler operators the tools to maintain an efficient and effective boiler …Learn More

  • Water Softener | CleanBoiler.org

    Which treatment is most appropriate depends on the water supply quality, the purity requirements of the boiler, and to some extent – the budget. Water Hardness is measured in grains per gallon or ppm. The conversion is 17.1 ppm = 1 grain. One cubic foot of softener resin is typically good for 30,000 grains in …Learn More

  • Part II. Energy Efficiency by Sectors Energy Efficiency in

    capacity steam boiler Available in sizes that are far greater than the fire tube design. Up to several million pounds per hour of steam. Able to handle higher pressures up to 5,000psig Recover faster than their firetube cousin Boiler Softener Learn More

  • Water for the Boiler - Spirax Sarco | First for Steam

    Water for the Boiler. The operating objectives for steam boiler plant include: Safe operation. Maximum combustion and heat transfer efficiency. Minimum maintenance. Long working life. The quality of the water used to produce the steam in the boiler will have a profound effect on meeting these objectives.Learn More

  • How to Calculate Softener Capacity - Chem-Aqua

    Water softeners are ion exchange systems designed to remove scale-forming calcium and magnesium ions prior to boiler, cooling, and reverse osmosis systems. The amount of hardness a softener can remove between regenerations is known as the softener capacity and can be expressed either in grains or in gallons. Capacity is important when sizing, configuring, or troubleshooting a softener.Learn More

  • water softening systems,water softeners,water soften,water

    These sodium compounds replace calcium and magnesium compounds, effectively reducing lime hardness build up and increasing the life of your boiler or heat exchanger. Water softener systems provide increased flow rates, additional capacity and continuous, uninterrupted softened water.Learn More

  • Water softener use for a steam boiler - good idea

    Mar 21, 2012 · water softener for untreated steam boiler - good idea? the steam boiler is a commercial boiler (14 sections cast iron) it is not being treated chemically and the makeup water quality is on the very hard side. 0. nicholas bonham-carter Member Posts: 8,488. March 2012.Learn More

  • BULLETIN 301-WSS 9C PARKER BOILER CO. WATER …

    When sizing a water softener for a Steam Boiler system many factors affect the selection. Among them are 1) Boiler size. 2) Hours of operation. 3) Hardness of the water. 4) Amount of condensate return. 5) Desired time between regeneration. 6) Maximum flow rate. 7) frequency of blowdown. A Parker Water Softener can be selected by determining the Learn More

  • Boiler Water Treatment Equipment - Robert B. Hill Co.

    When using industrial water softeners for boiler feed, there are several commons factors that go into design: Boiler HP. The rating of small boilers is by horsepower. One horsepower is the ability to evaporate 34.5 lbs. of water into steam at 212 degrees F and above. Example 1: 100 hp x 34.5 = 3450 lbs. of steam per hour.Learn More

  • Determining Softener Size for Boiler Feedwater | Complete

    Softener should be sized to enable removal of daily amount of grains with half the maximum capacity of the system. The continuous flow should be achieved at around 5 gpm per cubic foot of resin or less. The stringent requirements to meet very low hardness levels …Learn More

  • Softeners - Nobel Srl

    Recommended for treatment of drinking water. Suitable for all softeners of small and medium capacity. Softener series AS C Duplex. (ie steam boiler feed water) Flow rate up to 20 m³/h. P max 8,6 bar. Softener series AS CT. Automatic softeners. Designed for all residential applications, from flat or villa to a small blocks of flat. Flow Learn More

  • WBT Steam Boiler Supply, Rental and Maintenace services

    LAUNDRY BOILER - Oil/Gas (40 - 350 kg/h) KSA SERIES - Made in Saudi Arabia . Steam generation capacity: 40 kg/h - 350 kg/h. Operating Pressure: 1-8 BarLearn More

  • Water Softeners - Complete Boiler Room Solutions

    Determining Softener Size for Boiler - Complete WaterLearn More

  • Water Softener Sizing For Parker Steam Boilers - Parker Boiler

    In most cases, on single boiler installations operating 8 hours per. day, with more than 50% condensate return, water softener sizing is as follows: 1-1/2 – 50 H.P. FGAKefid (769,500 PPM) 70 – 115 H.P. FGAKefid (1,539,000 PPM) *150 H.P. FGA-120-2 (2,052,000 PPM) *Flow rate of float valves requires 2" softener …Learn More